Our website uses cookies to enhance your experience. By continuing to use our website, you are agreeing to our use of cookies. Necessary cookies are always enabled. You can read more about our Cookie Policy in our Privacy policy
Strictly Neccessary
Essential cookies enable core website functionality, such as secure logins and preference settings, without tracking personal activities or collecting data for ads. They ensure the site's proper operation and legal compliance, remaining always active
Preferences
Preference cookies enhance your browsing by remembering settings like language and regional preferences, tailoring the site to your needs without tracking activity across other websites
Statistical
Statistics cookies gather anonymous data on site interactions and page visits to help improve functionality, ensuring a smoother user experience without personally identifying users
Marketing
Marketing cookies track browsing habits across websites to deliver relevant, tailored ads, enhancing value for publishers and advertisers by focusing on individual preferences.
Please be aware that from 24th August 2023, all professional and industrial workers (employed or self-employed), using mixtures containing diisocyanates at a concentration of 0.1% or more (e.g., insulation and filler foams used in construction etc), must undergo mandatory training.
The TriRoof Polyurethane Roofing Topcoat is a one component; moisture triggered elastomeric urethane coating specifically developed as a high-performance waterproofing membrane topcoat for use on roof surfaces. The TriRoof Polyurethane Roofing Topcoat is to be used with the TriRoof Polyurethane Roofing Basecoat for the full waterproofing membrane system.
Product Features
• Good application characteristics for an easy by-hand application.
• Short cure times allowing the product to be over coated quickly.
• Outstanding waterproofing properties.
Applications
The TriRoof Polyurethane Roofing Topcoat is designed for use in applications where a seamless waterproof system is required on structurally sound roof areas. It is recommended that the product is applied at +5 to +35°C.
System Application
A coat of the TriRoof Polyurethane Roofing Basecoat should be laid at a coverage rate of 1.2 L/m2 with 225gsm chopped strand matting embedded into the material. Once the base coat has reached a suitable overcoating window, a coat of TriRoof Polyurethane Roofing Topcoat can be applied at a coverage rate of 0.75 L/m2 for a 15-year system, 1.0 L/m2 for a 20-year system or 1.75L/m2 for a 25-year system.
Curing
The TriRoof Polyurethane Roofing Topcoat should be allowed to cure for a minimum 8 hours at 19°C prior to overcoating. The cure time will be extended at low temperatures and low humidity.
For full technical information and application guidelines, we strongly recommend reviewing the TDS available to download from the Technical Downloads tab of this product.
Warning! Persons already sensitised to diisocyanates may develop allergic reactions when using this product. Persons suffering from asthma, eczema or skin problems should avoid contact, including dermal contact, with this product. This product should not be used under conditions of poor ventilation unless a protective mask with an appropriate gas filter (i.e. type A1 according to standard EN 14387) is used.’ Protective gloves to be supplied with this product. Please be aware that from 24th August 2023, all professional and industrial workers (employed or self-employed), using mixtures containing diisocyanates at a concentration of 0.1% or more (e.g., insulation and filler foams used in construction etc.), must undergo mandatory training. Danger Contains isocyanates. May produce an allergic reaction Hazard statements H226 - Flammable liquid and vapour H332 - Harmful if inhaled H315 - Causes skin irritation H319 - Causes serious eye irritation H317 - May cause an allergic skin reaction H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled H361d - Suspected of damaging the unborn child H412 - Harmful to aquatic life with long-lasting effects Precautionary statements IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Avoid breathing dust/fume/gas/mist/vapours/spray. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Wear protective gloves/protective clothing/eye protection/face protection. In case of inadequate ventilation, wear respiratory protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.Brand | Description |
History | Color sit amet, consectetur adipiscing elit. In gravida pellentesque ligula, vel eleifend turpis blandit vel. Nam quis lorem ut mi mattis ullamcorper ac quis dui. Vestibulum et scelerisque ante, eu sodales mi. Nunc tincidunt tempus varius. Integer ante dolor, suscipit non faucibus a, scelerisque vitae sapien. |